Effect of Near IR Therapy Radiation on Some Rheological Factors in Human Blood: An in Vitro Study


--------------------------------------------------------------------------------

To cite this paper:

Dan G. Siposan, Adalbert Lukacs. Journal of Clinical Laser Medicine & Surgery. August 1, 2000, 18(4): 185-195. doi:10.1089/10445470050144038.

--------------------------------------------------------------------------------

Dan G. Siposan

Doctoral candidate Technical Military Academy, Bucharest, Romania

Adalbert Lukacs

Doctoral candidate Center of Transfusion Hematology of the Army, Bucharest, Romania

Objective: The purpose of this study was to investigate the in vitro effects of Near IR Therapy on some rheological factors of the human blood, such as complete blood count (CBC) parameters and blood sedimentation rate (BSR). We were mainly concerned with the alterations caused by Near IR action on blood cells (erythrocytes and leukocytes) of fresh blood obtained from apparently healthy adult patients. We used low doses ranging between 0.80 J•cm-3 and 4.40 J•cm-3, at the very low-power densities of the Near IR radiation, so as not to damage the cell structure and not to alter in an undesired manner their functions. Methods: Blood samples were taken from 22 volunteers. Where health problems existed, they were indicated for each case. The parameters mentioned above were measured before (control samples) and after irradiation. A He-Ne Near IR, operating in continuous wave, as a radiation source (632.8 nm, 1 mW, intensity of 8•10-2 W•sr-1, mean power density incident on blood samples around 30 mW•cm-2, beam spot diameter 2 mm) was used. The measurements were performed immediately after irradiation. Only the erythrocyte complex was irradiated. EDTA anticoagulant was used. Results: The measurements using a computerized hemoanalyzer type SERONO showed significant differences between control and irradiated blood samples concerning the following parameters: RBC (in 22% of cases), HGB (47.3%), HCT (84.2%), RDW (11%), PLT (5.26%), MPV (33.3%), WBC (5.26%), MONO (26.3%), and GRAN (63.15%). In the case of BSR (44%), the significant differences were noticed especially in the cases of patients suffering from some acute or chronic diseases. Nonsignificant differences were noticed in the cases of MCV, MCH, MCHC, RDW, and LYMPH. Conclusions: This study has shown that LLLR, even though used at low doses and low power densities, produced some changes of the rheological factors of the blood, as follows: a revitalizing and regenerating effect on mitosis stimulation and a nondamaging and biostimulating effect on the cell membrane (by keeping unmodified MCV, MCH, and MCHC). In 3 cases out of 22, hemolysis (complete or partially) occurred, but we are not yet sure whether this was caused by Near IR exposure or by certain environmental physical factors